產品詳情
技術規格
型號和配件
文檔與軟件
更多信息
聯係我們
Encircled Flux Multimode Adapter
New generation of Multimode Fiber Adapters adds full standards compliant fiber certification capability
A light source and power meter are used to measure the power loss and length of optical cables at 850 and 1300 nm. Certification of Multimode fibers has often been a contentious issue due to the inherent uncertainties in the measurement process. ISO/IEC and TIA have recently adopted a Encircled Flux (EF) standard that standardizes the launch condition for the light sources used in Multimode test equipment. The WireXpert’s new EF compliant adapters give you guaranteed compliance to the EF standard IEC 61280-4-1.
EF Multimode Adapter
Why EF Multimode Adapter?
One cable certifier to test copper- as well as multimode-, singlemode and MPO/MTP-fiber installations.
Improve productivity of technicians with easy setting and fast testing
Test single fiber links, trouble-shoot links with light source and power meter tools
Easy pictorial work-flow makes it easy to avoid human errors in testing
EF Multimode Adapter
Features
Compliant to IEC- 61280-4-1 EF standards and IEC-14763-3 |
Provides validation to different modal behaviors of various fiber optic manufacturers |
Interchangeable robust SC, LC and ST adapter for EF kit |
Provides troubleshooting with built-in Visual Fault Locator (VFL) |
Improves repeatability of measurements |
Reduces insertion loss variation between laboratory and field instruments |
EF Multimode Adapter
Physical characteristics
Input Connector | Interchangeable connector with LC, ST and SC options) Standard kit ships with SC |
Detector Type | InGaAs |
Wavelengths | 850nm, 1300nm |
Power Measurement Range | -15 dBm to -60 dBm at 850nm, -15 dBm to -70 dBm at 1300 nm |
Measurement Linearity | <±0.1 dB in the power measurement range |
Re-calibration Period | 1 year |
Specification | MMEF |
Input/Output Connectors | Interchangeable connector with LC, SC, ST options |
Launch Condition | Encircled Flux compliant to IEC 612480-4-1 |
Fiber Types Tested | 50/125, 62.5/125 |
Source Type and Wavelengths | 850/1300 nm |
Length Measurement Accuracy | ±1.5m |
Output Power (Nominal) | > -20 dBm at 850, 1300 nm |
Output Power Stability | ±0.02 dB after 3 minute warm up time |
Output Power | >-4dBm, < -1 dBm Continuous, blinking mode CW output SC connector |
Operating Wavelength | 650 nm |
Output Modes | Pulsed, Continuous |
Connector Adapter | 2.5mm |
Laser Safety | Class II |
Operating Temperature | 0° C to 45° C |
Storage Temperature | -20° C to 50 °C |
Safety | EN61010 |
EF Multimode Adapter
Delivery
WX_AD_EF_MM2
Encircled flux compliant multimode fiber adapter set (850nm and 1300nm). includes a pair of FC-SC modally transparent test cords, a pair of SC-SC tail cordsand cleaning kit
WX_AC_LC_EF_MM_CORDKIT
LC test cord kit for EF-compliant multimode adapter, includes a pair of modally transparent FC-LC test cords, a pair of LC-LC simplex tail cords, a pair of interchangeable lc adapters and a pair of LC-LC duplex adapters
WX_AC_EF_MM_REFCORD_SC2
A pair of modally transparent FC-SC test reference cords and a pair of SC-SC tail cords
WX_AC_MM_ST_KIT
A pair of EF mm 50um FC to ST reference cords, a pair of ST to ST mm 50 mm reference cord, 2 qty ST adapter
訂購:Sofing WX_AD_EF_MM2多模光纖測試模塊(原賽博Psiber)
我要評論: | |
昵 稱: |
|
內 容: |
(內容最多500個漢字,1000個字符) |
驗證碼: | |
相關資訊
- 7類模塊GG45介紹篇-及附錄DTX1800七類方案
- FLuke DTX1800經典之王之最後的版本V2.74軟件
- 3步處理射頻幹擾問題
- 為什麼所有光纖數都是2和8的整數倍?
- DTX-1800輔機查看電量【圖解版】
- fluke DSX-5000中TCL與ELTCTL是什麼意思?測試不過怎麼辦?
- DTX-1800係列全球服務到期通知
- 選擇福祿克DSX-5000的五大理由
- DTX-1800或者DSX5000:“壞的跳線在主機端”提示或“壞的跳線在遠端”
- 【冬去春來,辭舊迎新】深圳乐鱼棋牌mac更新 2017-2018年會圓滿成功
- 福祿克 Fiber OneShot PRO當不接線的時候 長度顯示1M
- 福祿克DSX5000如何調整NVP使得長度測試準確
- Fluke CableIQ電纜鑒定測試儀(CIQ-100,CIQ-KIT)的 USB 驅動程序(WIN7、WIN8、WIN10)
- Linkrunner G2測試POE設備案例(LR-G2-KIT)
- 深圳乐鱼棋牌mac更新 與東莞某線纜廠達成福祿克DTX-1800合作項目
- 如何確保綜合布線屏蔽的完整性?
- NETSCOUT Aircheck G2與Airmagnet WiFi排障案例分析
- 《GB/T 32420-2015 無線局域網測試規範》宣貫會深圳站邀請函
- 福祿克DSX-5000如何更新軟件版本
- 數據中心機房乐鱼开奖app 解決方案
產品推薦
客戶案例
谘詢熱線:
13798421872
郵件: sales@faxytech.com
電話:0755-8399-9818
地址:深圳市福田區華強北路華聯發大廈602室
共有-條評論【我要評論】